Supplied by AC electrical network, the TRU provides emergency 28 VDC voltage through a TRU box for protection, logic controls, monitoring.
This TRU box shall perform the following functions:
- Connection of the various power sources to the network
- Electrical power distribution networks’ protection
- Protection against over current, over voltage, under voltage
- Diode failure detection
- Built-in tests
- CAN and ARINC status communication
Key features
- 28 Vdc/180 Amps
- 1 input/2 outputs
- Protection of power outputs
- Connection and distribution to sub-systems
Applications
- Helicopters
- Business Jet
Specifications
Electrical
Input voltage
28 VDC/180 amps
CAN and ARINC bus communication
Digital signal inputs (overheat and failure status, distribution commands)
Over-current and reverse current protection
Diode failure detection
Integrated PBIT and CBIT
CAN and ARINC bus communication
Digital signal inputs (overheat and failure status, distribution commands)
Over-current and reverse current protection
Diode failure detection
Integrated PBIT and CBIT
Output
28VDC/90amps
Physical
Width
225 mm
Height
120 mm
Depth
115 mm
Weight
< 2 kg
Environmental
Temperature
-40°C to +70°C (normal operating conditions)
Certification approvals
DO254 level B
RTCA/D0160D
ABD 100.1.8
RTCA/D0160D
ABD 100.1.8
Note: Due to continuous process improvement, specifications are subject to change without notice